OWON XSA800 Series Spectrum Analyzer Frequency Range from 9 kHz up to 1.5 GHz resolution ratio 1280×800 9 inches LCD XSA805/815
- Pre-Order Available (Estimated ±15 Day Delivery)
- 7 day unit replacement guarantee(Video Unboxing Required)
- Including shipping costs, sent by Supplyinx.com
- Pick up at a supplyinx.com collection point is possible
- 24/7Customer service
Description
- Hign-concerned Chemical: None
- Model Number: XSA805(TG)XSA810(TG)XSA815(TG)
- Interface: LAN,USB
- Average Noise Level: -150dBm & Above
- DIY Supplies: ELECTRICAL
- Brand Name: owon
- Origin: Mainland China
- Certification: CE
- communication interface: USB HOST, USB DEVICE, LAN, earphone port, HDMI

XSA800 Series
By purchasing a spectrum analyzer and near-field probe ORF5060, you can get a free EMI tracking kit worth $200
Spectrum Analyzer
+ Frequency Range from 9 kHz up to 1.5 GHz
+ -160dBm Displayed Average Noise Level
+ Phase Noise -80dBc/Hz @1Gz and offset at 10KHz
+ Total Amplitude Accuracy <0.7dB
+ 1Hz Minimum Resolution Bandwidth (RBW)
+ EMI pre-compliance test kit, optional EMC test software
+ Standard tracking generator hardware, can be remotely upgraded according to needs
+ 9 inches LCD
+Performance Specifications
Model |
XSA805(TG) |
XSA810(TG) |
XSA815(TG) |
Frequency |
|||
Range |
9kHz-500MHz |
9kHz-1GHz |
9kHz-1.5 GHz |
Resolution |
1Hz |
||
Frequency span |
|||
Range |
0 Hz,100 Hz to maximum frequency of device |
||
Accuracy |
± span /(swept points -1) |
||
Internal reference |
|||
Reference frequency |
10 MHz |
||
Reference frequency accuracy |
±[(days from last calibrate × freq aging rate)+ temperature stability + initial accuracy ] |
||
Temperature stability |
<0.5ppm (15℃ to 35℃) |
||
Aging rate |
<1ppm/year |
||
Readout |
|||
Marker frequency resolution |
span/(the number of sweep points -1) |
||
Uncertainty |
±(freq indication × freq reference uncertainty +1%× span +10%× resolution bandwidth + Marker Frequency Resolution) |
||
Frequency counter |
|||
Resolution |
1 Hz,10 Hz,100 Hz,1 kHz |
||
Accuracy |
±(marker freq × freq reference uncertainty + counter resolution) |
||
Bandwidth |
|||
Resolution bandwidth (-3 dB) |
1Hz to 1MHz(in 1 to 10 sequence), 1MHz,3MHz |
||
Resolution filter shape factor |
<5 nominal(Digital implement, similar to Gauss Pattern) |
||
Accuracy |
<5% nominal |
||
Video bandwidth (-3 dB) |
1Hz to 1MHz |
Amplitude Specification |
|
Amplitude and electric level |
|
Amplitude measurement range |
DANL to +10 dBm, 100KHz to 10MHz,close the preamplifier DANL to +20 dBm, 10MHz to 1.5GHz, close the preamplifier |
Max input DC voltage |
50 VDC |
Max. continuous wave RF power |
+20dBm (100mW), attenuation= 40dB |
Max. damage level |
+30dBm(1W) |
Displayed average noise level(DANL)attenuation = 0 dB, RBW = VBW = 100 Hz, sample detector, trace average ≥ 50, 20℃ to 30℃ , input impendence = 50 Ω |
|
Preamp off |
-95 dBm (typical), < -88 dBm ( 9 kHz to 1 MHz) |
-140 dBm (typical), <-130dBm (1MHz~500MHz) |
|
-138 dBm (typical), <-128 dBm (500MHz~max) |
|
Preamp on |
-135 dBm (typical), <-128 dBm ( 9 kHz to 1 MHz) |
-160 dBm (typical), <-150 dBm (1MHz~500MHz) |
|
-158 dBm (typical), <-148 dBm (500MHz~max) |
|
Phase noise |
20 ℃ to 30 ℃,fc=1 GHz |
Phase noise |
<-80 dBc/Hz @10 kHz offset, |
<-100 dBc/Hz @100 kHz offset |
|
<-115 dBc/Hz @1 MHz -500MHz offset |
|
Level display range |
|
Log scale coordinate |
0.01dB ~255dB |
Linear scale coordinate |
0 to reference level |
level unit |
dBm, dBuW, dBpW, dBmV, dBuV, W,V |
Points |
760 |
Number of traces |
5 |
Detectors |
Positive-peak, negative-peak, sample, normal, RMS, Average, quasi-peak (with EMIoption) |
Trace functions |
Clear write, Max Hold, Min Hold, View, Blank, Average, Trace math |
Frequency response |
|
|
20℃ to 30℃,30%~70% relative humidity, 10 dB input attenuation, reference 50 MHz |
Preamp off(fc≥9KHz) |
<0.7dB; |
Preamp on(fc≥9KHz) |
<1.0 dB; |
Accuracy |
|
RBW Switching Uncertainty |
Relative to 10 kHz RBW <0.1 dB |
Input Attenuation Switching Uncertainty |
20℃ to 30℃, fc=50 MHz,Preamplifier Off, 10dB RF attenuation,input signal 0~40 dB <0.5 dB |
Absolute Amplitude Uncertainty |
20℃ to 30℃, fc=50 MHz,peak detector, 10 dB RF attenuation,preamplifier off, input signal level =-10 dBm |
Reference Level Range |
-80 dBm to +30 dBm, in 1 dB step |
Reference Level Resolution |
Log scale 0.01 dB; linear scale 4 digits |
Uncertainty |
95% confidence level, S/N > 20 dB, RBW = VBW = 1 kHz, preamplifier off, attenuation = 10 dB, -50 dBm < input level ≤ 0 dBm, fc > 10 MHz, 20℃ to 30℃ |
< 0.7 dB |
|
VSWR |
input≥ 10 dB,300 kHz to max; |
<1.5,nominal |
|
Distortion and spurious response |
|
Second harmonic distortion |
fc ≥ 50 MHz,Preamp off, signal input -20 dBm, 10 dB RF attenuation, 20 ℃ to 30 ℃ |
> +45 dBm |
|
Third-order intermodulation |
fc ≥ 50 MHz, two -20 dBm tones at input mixer spaced by 200 kHz, attenuation = 0 dB |
> +10 dBm |
|
1 dB Gain Compression |
fc ≥ 50 MHz, 0 dB RF attenuation,Preamp off , 20 ℃ to 30 ℃ |
>0 dBm, nominal |
|
Residual response |
connect 50 Ω load at input port,0 dB input attenuation,20 ℃ to 30 ℃ |
<-90dBm,nominated |
|
Intermediate frequency |
<-60 dBc |
System related sidebands |
Referenced to local oscillators, referenced to A/D conversion, referenced to subharmonic of first LO, referenced to harmonic of first LO |
<-60 dBc |
|
Input related spurious |
-30 dBm signal at input mixer,20 ℃ to 30 ℃ |
<-60 dBc |
|
Sweep time and triggering |
|
Sweep time |
SPAN ≥ 100 Hz 10ms to 3000s zero sweep width 10ms to 3000s |
Sweep time uncertainty |
SPAN≥ 100 Hz 5%(nominal) zero sweep(Sweep time >1 ms) 5%(nominal) |
Mode |
Continue, single |
Trigger |
Free run, video, external |
External trigger level |
5 V TTL level |
Tracking generator |
|
Output frequency range |
100 kHz to 1.5 GHz(Tracking generator) |
Output power level range |
-40 dBm to 0 dBm |
Output power level resolution |
1dB |
Output flatness |
±3dB |
Tracking generator spurious |
Harmonic spurious -30 dBc (Tracking generator output power -10 dBm) Non-harmonic spurious -40 dBc (Tracking generator output power -10 dBm) |
Tracking source to input terminal isolation |
-60 dB (Tracking generator output power 0 dBm) |
Maximum safe reverse level |
Average total power:+30 dBm,DC : ±50 VDC |
Inputs and Outputs |
|
Front panel RF input connector |
50 Ω,N-type female |
Front panel track generator output |
50 Ω,N-type female |
Internal/ External Reference |
50 Ω,N-type female |
External Trigger Input |
50 Ω,N-type female |
Communication port |
USB HOST, USB DEVICE, LAN, earphone port, HDMI |
General technical specification |
|
Display |
TFT LCD,9 inches (1280*800) |
Weight (without package) |
About 3.7 kg |
Dimension (W × H × D) |
375mm*185mm*120mm |
Working temperature |
0℃ to 40 ℃ |
Storage temperature |
-20 °C to +60 °C |
Power |
100V – 240V 50/60Hz |
Package include
1*OWON XSA800(TG=Tracking generator) Spectrum Analyzer
1*Power Cord
1*N-SMA Adaptor
1*N-BNC Adaptor
1*USB Cable
1*Quick Guide